According to the relevant personnel, geothermal floor because of its special features and geothermal system complexity, wpc material porch floor compared with ordinary flooring, geothermal floor maintenance and maintenance has its unique place in the heating and moisturizing aspects to pay special attention. First, the installation of floor insulation should be noted that the use of geothermal floor, consumers must pay attention to step by step to the floor and floor heating. Installation, the surface temperature should be maintained at about 18 ℃. In the installation, the cement ground temperature gradually increased daily 5 ℃, until the standard up to about 18 ℃. During the first 3 days of installation, the temperature should be maintained for 3 days before the temperature rises as required and only 5 ° C per day. Second, Corrosion Resistant wpc outdoor wall panel pay attention to heating should be gradual.The first use of geothermal heating, attention should be slow heating. The first day of use, the first three days of heating to gradually warming: the first day of water temperature 18 ℃, the next day 25 ℃, the third day 30 ℃, the fourth day to rise to normal temperature, the water temperature 45 ℃, surface temperature 28 C to 30C. Can not heat up too fast, too fast, then the floor may be due to expansion cracking distortion phenomenon. Third, a long time after the re-opening, heating should be gradual, long after the re-opening of the geothermal heating system, but also like the first use as strictly in accordance with the heating process temperature. Fourth, the surface temperature can not be too high, it should be noted that the use of geothermal heating,Anti Corrosive outdoor flooring the surface temperature should not exceed 28 ℃, the water pipe temperature can not exceed 45 ℃, if more than this temperature, will affect the life of the floor and the use of life cycle. General family, the winter room temperature reached 22 ℃ or so, it has been very comfortable, the normal warming, then, will not affect the use of geothermal floor. 5, turn off the geothermal system, pay attention to the gradual cooling, as the season goes on, when the weather is warm up, indoor no longer need geothermal heating system, should pay attention to close the geothermal system should also have a process, the floor cooling process should be gradual, Not drop, if the cooling rate is too fast,New materials-garden-decoration it will also affect the life of the floor. 6, the room is too dry, you can consider humidification, dry climate in winter, coupled with the use of geothermal heating, wood flooring in the case of long-term high temperature, easy to dry, then the owners need to humidify the room to avoid wood floor deformation, moisture Can not be ignored.